Crash logs for a single crash are written all at once so that the logs are easier to read if there are crashes of multiple processes at the same time.Crash logs from other processes are done through miglogd.
is the number of second to log crash logs for a particular process l The miglogd daemon is the only one to write crash logs directly. This limit can be edited using the command: diagnose debug crashlog interval
#Fortinet download pcap cli windows
Windows AD(DCE-RPC,DNS,KERBEROS,LDAP,LDAP_UDP,SAMBA,SMB,) TELNET,LDAP,MS-SQL,MMS,KERBEROS,SQUID,NTP,FTP,CVSPSERVER,test,AFS3,POP3,Internet-Locator-Įmail Access(DNS,IMAP,IMAPS,POP3,POP3S,SMTP,SMTPS,) X-WINDOWS,SMB,SAMBA,TRACEROUTE,NFS,WINS,L2TP,IMAP,GOPHER,SIP-MSNmessenger,SYSLOG,DHCP6,
ONC-RPC,NNTP,SMTP,QUAKE,PC-Anywhere,TFTP,NONE,SSH,RSH,IMAPS,LDAP_UDP,SIP,RIP,PING,PING6, WINFRAME,DNS,DCE-RPC,H323,RLOGIN,IRC,UUCP,_Webadmin,HTTPS,WAIS,FINGER,REXEC, RAUDIO,SNMP,TIMESTAMP,RADIUS-OLD,DHCP,AOL,MGCP,SMTPS,INFO_REQUEST,HTTP,SCCP,SOCKS,PPTP, Port(111), name(ONC-RPC) extra: (ONC-RPC) (NFS) icmp port(1), name(test) port(8), name(PING) port(13), name(TIMESTAMP) port(15), name(INFO_REQUEST) port(17), name(INFO_ADDRESS) general Only the first 5 of each grouping has been included. This output has been edited down to conserve space. diag test app miglogd 106 Example output: L diag npc np6 gmac-stats – Shows the GMAC MIBs counters l diag npc np6 gmac-stats-clear – Clears the GMAC MIBS counters l diag npc np6 gige-port-stats – Shows the GIGE PORT MIBs counters l diag npc np6 gige-port-stats-clear – Clears the GIGE PORT MIBs countersĭiagnose command to show firewall service cache (355819)Ī diagnostic command has been added to dump out the service name cache kept by the miglogd daemon for each individual VDOM. These options were available in 5.2.x but were not in 5.4.0 The following diag npc np6 commands have been reintroduced into 5.6.0. New diagnose features added to FortiOS 5.6.Īdd missing “diag npu np6 …” Commands (305808) The command diagnose sys fips kat-error has added additional options, like ECDSA. New diagnose sys fips kat-error options (440186) Suspended failure = 0 push failure = 0 block write counter = 0 un-block write counter = 0 un-matching failure = 0 ips action failure = 0 ips action permit = 0 ips action deny = 0 ips action bypass = 0 To correct this, a new command was created.ĭiagnose wad stats ips listĭiagnose wad stats ips list IPS status unix stream counter = 0 active sess counter = 0 ips provider counter = 0 not running failure = 0 all busy failure = 0 conn close counter = 0 conn connected counter = 0 conn failure = 0 zero len failure = 0 When WAD IPS scanning took place with a failed result, the message caused the IPS sensor to mistakenly record the event as something triggering the sensor. New command to monitor IPS stats (414496) While there is no change to the syntax of the commands, the LLDP diagnose commands are allowed to execute without switchid/portid parameters configured.
LLDP diagnose commands easier to execute (413102)